What is new in the software solution Power Path V25 updated version?


The POWER PATH team is constantly developing and improving the Power Path® solution. Behind the scenes, our development and support teams work daily to create, improve and research new functionalities, providing customers with new and innovative approaches to power line design. In front of you is What is new document which describes what the latest version brings.



The latest version of the Power Path solution is Power Path V25, build 25.2.08. Published in August 2025.



Enjoy in exploring and using new functionalities!


Forword


Power Path offers numerous benefits for power line design and project development, including:

  1. 2D design and advanced 3D BIM modeling
  2. Generation of calculation reports
  3. Customization of power line components
  4. Reduction of information-sharing restrictions
  5. Increased project transparency
  6. Enhanced project visualization
  7. Import/export of IFC (BIM) models
  8. Import/export of SHP (GIS) data
  9. Integration of online maps and WMS data
  10. Seamless project sharing with all data for the next phases (construction, operation, maintenance and management)

 

Power Path solution is not just limited on power line design process, it is a powerful CAD and BIM solution for 2D drafting and 3D BIM modeling in AEC (Architecture, Engineering and Construction) industry.

 

Always get the latest version for the best Power Path experience.


Upgraded or/and extended existing commands and functionalities for power line design


- Add Weather Conditions and Edit Weather Conditions

When the user defines a positive value for the user-defined temperature, the input options for ice load is automatically disabled, meaning their values are considered to be 0. When a negative value is defined, the user is given the option to input and define the ice load.



 With this upgrade, the chance of defining incorrect conditions when creating the weather conditions definition is reduced.


- Create Sag Tension Report

The report now includes the length of the conductor for each temperature listed, so in addition to sag and tension, the report also contains conductor lengths at different temperatures.


With this upgrade, in addition to the 3D graphical display that already existed, a numerical value of the catenary length for different temperatures is now available.


- Create Quantity Report

The report now includes the length of the conductor, so in addition to other quantities, it also shows values representing conductor lengths.


With this upgrade, this report provides information for lengths of all used conductors for selected power line.


- Create Support Report

The report now includes calculations of reduced forces and moments at the top of the support, so in addition to load components, it also contains the resultant force and moment values.


With this upgrade, the report provides information on summarized loads on the support.


- Settings

Units for moment have been added to the settings.


The added setting for unit moment (in Other units) allows users to choose the desired unit for the generated results in reports.



Fixed existing commands and functionalities 


- Create Sag Tension Report

When generating the Sag - Tension report under previously defined weather conditions without ice load, the report will now be created with correct critical span values and will no longer display the value “infinite”.


The issue has been fixed in this version.


- Add Support Data

A fix has been implemented regarding the ability to add attachment points when adding new supports.


The issue has been fixed in this version.


- Panels Layers and Attachments

Panels Layers and Attachments can be enabled on the docked sides (left or right).



These issues have been fixed in this version.



Instructions for installing the latest version and/or build of Power Path


If you want to install the latest version and/or the latest build of the version, you need to start the installation process and follow the steps described in the following guides:


For example, if you already have Power Path V25 with build 25.1.07 installed, and you are now installing Power Path V25 with build 25.2.08, at the end of the installation the program will prompt you to confirm the upgrade of user files, as shown here:

Our recommendation is to choose the "Overwrite" option.


If you are installing Power Path V25 with build 25.2.08 for the first time, you will not see the dialog for upgrading user files.


 

Always get the latest version for the best Power Path experience.


Try Power Path V25


If you're ready to start creating power line projects using the BIM approach, simply import your data and use Power Path for all your 2D drafting and 3D modeling needs in engineering projects.


To download and try Power Path V25, visit the product website https://www.power-path.com and submit a request.


Thank you for choosing Power Path, we hope you will enjoy in using and it will make the design process easier for you!


Software developer: POWER PATH DOO

email: contact@power-path.com 

web page: https://www.power-path.com